Hi, I'm currently implementing an ATM network. There are several SUN Ultra 1
with ATM card involved. The problem is, if I set up a PVC connection with VPI
<> 0, the Ultra will not respond. Only if I use VPI = 0 (VCI > 31 of course),
the Ultra will respond. Has anybody experienced this problem? Is it the
limitation of the card itself? My real concern to this phenomenon is in the
case of SVC connection as VPI/VCI will be assigned thru signalling (therefore,
a VPI <> 0 would probably be set up dynamically).
Any comments will be appreciated.
Thank you.
=========================================================================
Si tu es contre Dieu, tu es contre l'homme
Aldrian Gintingsuka
System Engineer
PT Mitra Integrasi Informatika
Phone: 62-21-251-1360 ext. 1414
Fax: 62-21-251-2748